12 DATA USED FOR POSITIONING CONTROL
12.1 Types of Data
383
12
■
Monitoring the speed
■
Monitoring the status of servo amplifier
Monitor details
Corresponding item
Monitor the
current
speed
During independent axis control
Indicates the speed of
each axis
[Md.22] Feedrate
During
interpolation
control
When "0: Composite speed" is set for "[Pr.20]
Interpolation speed designation method"
Indicates the
composite speed
When "1: Reference axis speed" is set for "[Pr.20]
Interpolation speed designation method"
Indicates the
reference axis speed
Monitor "[Da.8] Command speed" currently being executed.
[Md.27] Current speed
Constantly indicates the speed of each axis
[Md.28] Axis feedrate
Monitor the current target speed
[Md.33] Target speed
Monitor the command speed at speed control mode or continuous operation to torque control mode in the
speed-torque control
[Md.122] Speed during command
Monitor details
Corresponding item
Monitor the real current value "feed current value - (command pulse - feedback pulse)".
[Md.101] Real current value
Monitor the pulse droop.
[Md.102] Deviation counter value
Monitor the motor speed of servo motor.
[Md.103] Motor rotation speed
Monitor the current value of servo motor.
[Md.104] Motor current value
Monitor the servo amplifier type of each axis.
[Md.105] Connected device
Monitor the software No. of servo amplifier.
[Md.106] Servo amplifier software No.
Monitor the parameter No. that an error occurred.
[Md.107] Parameter error No.
Monitor the status (servo status) of servo amplifier.
[Md.108] Servo status1
[Md.119] Servo status2
[Md.125] Servo status3
[Md.500] Servo status7
• Monitor the percentage of regenerative power to permissible regenerative value.
• Monitor the content of "[Pr.91] Optional data monitor: Data type setting 1" at optional data monitor data type
setting.
[Md.109] Regenerative load ratio/Optional
data monitor output 1
• Monitor the continuous effective load torque.
• Monitor the content of "[Pr.92] Optional data monitor: Data type setting 2" at optional data monitor data type
setting.
[Md.110] Effective load torque/Optional data
monitor output 2
• Monitor the maximum generated torque.
• Monitor the content of "[Pr.93] Optional data monitor: Data type setting 3" at optional data monitor data type
setting.
[Md.111] Peak torque ratio/Optional data
monitor output 3
Monitor the content of "[Pr.94] Optional data monitor: Data type setting 4" at optional data monitor data type
setting.
[Md.112] Optional data monitor output 4
Monitor the status of semi closed loop control/fully closed loop control.
[Md.113] Semi/Fully closed loop status
Monitor the alarm of servo amplifier.
[Md.114] Servo alarm
Monitor the option information of encoder.
[Md.116] Encoder option information
Monitor the driver operation alarm number.
[Md.502] Driver operation alarm number
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......