388
12 DATA USED FOR POSITIONING CONTROL
12.2 List of Buffer Memory Addresses
12.2
List of Buffer Memory Addresses
The following shows the relation between the buffer memory addresses and the various items.
Do not use the buffer memory address that not been described here for a "Maker setting".
For the list of buffer memory addresses for positioning data, refer to the "Simple Motion Module Setting Function Help" of the
engineering tool.
Refer to the following for the list of buffer memory addresses for synchronous control.
MELSEC iQ-R Simple Motion Module User's Manual (Advanced Synchronous Control)
Basic setting
n: Axis No. - 1
Memory area
Item
Buffer memory address
Common parameters
[Pr.24]
Manual pulse generator/Incremental synchronous encoder input selection
33
[Pr.82]
Forced stop valid/invalid selection
35
[Pr.89]
Manual pulse generator/Incremental synchronous encoder input type
selection
67
[Pr.96]
Operation cycle setting
105
[Pr.97]
SSCNET setting
106
[Pr.150]
Input terminal logic selection
58000
58001
[Pr.151]
Manual pulse generator/Incremental synchronous encoder input logic
selection
58002
[Pr.152]
Maximum number of control axes
58003
[Pr.153]
External input signal digital filter setting 1 (SIN1 to 4)
External input signal digital filter setting 2 (SIN5 to 8)
External input signal digital filter setting 3 (SIN9 to 12)
External input signal digital filter setting 4 (SIN13 to 16)
External input signal digital filter setting 5 (SIN17 to 20)
58004
58005
58006
58007
58008
Positioning
parameters
Basic parameters 1
[Pr.1]
Unit setting
0+150n
[Pr.2]
Number of pulses per rotation (AP)
2+150n
3+150n
[Pr.3]
Movement amount per rotation (AL)
4+150n
5+150n
[Pr.4]
Unit magnification (AM)
1+150n
[Pr.7]
Bias speed at start
6+150n
7+150n
Basic parameters 2
[Pr.8]
Speed limit value
10+150n
11+150n
[Pr.9]
Acceleration time 0
12+150n
13+150n
[Pr.10]
Deceleration time 0
14+150n
15+150n
Detailed
parameters 1
[Pr.11]
Backlash compensation amount
17+150n
[Pr.12]
Software stroke limit upper limit value
18+150n
19+150n
[Pr.13]
Software stroke limit lower limit value
20+150n
21+150n
[Pr.14]
Software stroke limit selection
22+150n
[Pr.15]
Software stroke limit valid/invalid setting
23+150n
[Pr.16]
Command in-position width
24+150n
25+150n
[Pr.17]
Torque limit setting value
26+150n
[Pr.18]
M code ON signal output timing
27+150n
[Pr.19]
Speed switching mode
28+150n
[Pr.20]
Interpolation speed designation method
29+150n
[Pr.21]
Current feed value during speed control
30+150n
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...