8 CONTROL SUB FUNCTIONS
8.9 Other Functions
Setting method
To use the "Operation setting for incompletion of home position return", set the following parameters using a program.
n: Axis No. - 1
Refer to the following for the setting details.
Setting item
Setting
value
Setting details
Buffer memory address
[Pr.55]
Operation setting for incompletion of home
position return
Set the operation setting for incompletion of home
position return.
0: Positioning control is not executed.
1: Positioning control is executed.
87+150n