4 HIGH-LEVEL POSITIONING CONTROL
4.5 Start Program for High-level Positioning Control
161
4
Start time chart
The following chart shows a time chart in which the positioning data No. 1, 2, 10, 11, and 12 of the axis 1 are continuously
executed as an example.
■
Block start data setting example
■
Positioning data setting example
■
Start time chart
[RD77MS4 operation example]
Axis 1 block start data
[Da.11] Shape
[Da.12] Start data No.
[Da.13] Special start
instruction
[Da.14] Parameter
1st point
1: Continue
1
0: Block start
2nd point
0: End
10
0: Block start
Axis 1 positioning data
No.
[Da.1] Operation pattern
1
11: Continuous path control
2
00: Positioning complete
10
11: Continuous path control
11
11: Continuous path control
12
00: Positioning complete
Positioning start signal [Y10]
All axis servo ON
[Y1]
READY signal
[X0]
Start complete signal
([Md.31] Status: b14)
BUSY signal
[X10]
Positioning complete signal
([Md.31] Status: b15)
[Cd.3] Positioning start No.
V
t
Error detection signal
([Md.31] Status: b13)
[Cd.4] Positioning starting point No.
Positioning data No.
Dwell
time
12(00)
Operation pattern
1(11)
1st point
[buffer memory address 22000]
2nd point
[buffer memory address 22001]
11(11)
10(11)
2(00)
7000
1
-32767(8001H)
10(000AH)
PLC READY signal
[Y0]
Dwell
time
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......