APPENDICES APPENDIX
Appendix 3 Compatible Devices with SSCNETIII(/H)
631
A
Comparisons of specifications with MR-J3(W)-B
*1
Confirm the specifications of FR-A700 series for details.
*2
Parameters set in FR-A700 series are not controlled by Simple Motion module. Therefore, the operation is the same as when the servo
parameter "Rotation direction selection/travel direction selection (PA14)" is set as below during amplifier-less operation mode.
*3
Refer to each servo amplifier instruction manual for the servo amplifiers that can be used.
Item
FR-A700 series
MR-J3(W)-B
[Pr.100] Connected device
00004100H: FR-A700 (Inverter)
00004101H: FR-A700-NA (Inverter)
00004102H: FR-A700-EC (Inverter)
00004103H: FR-A700-CHT (Inverter)
00000100H: MR-J3-_B, MR-J3W-_B (2-axis type)
Control of servo amplifier parameters
Set directly by inverter. (Not controlled by Simple
Motion module.)
Controlled by Simple Motion module.
Detailed parameter 1
[Pr.116] FLS signal
selection
External input signals of FR-A700 series are
available.
External input signals of servo amplifier are
available.
[Pr.117] RLS signal
selection
[Pr.118] DOG signal
selection
Expansion parameter
[Pr.91] to [Pr.94]
Optional data monitor:
Data type setting
The following items can be monitored.
1: Motor load factor
4: Load inertia ratio
5: Position loop gain
6: Converter output voltage
8: Absolute position encoder multiple revolution
counter
20: Position feedback
21: Absolute position encoder single revolution
position
The following items can be monitored.
1: Effective load ratio
2: Regenerative load ratio
3: Peak
load
factor
4: Load inertia moment ratio
5: Model
loop
gain
6: Bus
voltage
7: Servo motor rotation speed
8: Encoder multiple revolution counter
12: Servomotor thermistor temperature
20: Position feedback
21: Encoder single revolution position
22: Selection droop pulse
24: Load side encoder information 1
25: Load side encoder information 2
Absolute position system
Not possible
Possible
Positioning control, Expansion control
Position control mode, Speed control mode,
Torque control mode
Position control mode, Speed control mode,
Torque control mode, Continuous operation to
torque control mode
Gain changing command
Valid
Valid
PI-PID switching command
Valid
Valid
Control loop (semi/fully) switching command
Invalid
Valid when using servo amplifier for fully closed
loop control
Servo parameter write/read
Not possible
Possible
Amplifier-less operation function
Possible
Possible
(Operates artificially as the followings during amplifier-less operation. Servo amplifier type: MR-J3-10B,
Motor type: HF-KP053 (resolution per servomotor rotation: 262144 pulses))
Driver communication
Not possible
Possible
Monitoring of servo parameter error No.
Not possible
Possible
Servo alarm/warning
Alarm codes/warning codes detected by FR-A700
series are stored in "Servo alarm/warning".
Alarm codes/warning codes detected by servo
amplifier are stored in "Servo alarm/warning".
Programming tool
MR Configurator2 is not available.
Use FR-DU07/FR-PU07 or FR Configurator.
MR Configurator2 is available.
Setting item
Setting value
Details
PA14
Rotation direction selection/travel
direction selection
0
Positioning address increase: CCW or positive direction
Positioning address decrease: CW of negative direction
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......