12 DATA USED FOR POSITIONING CONTROL
12.4 Positioning Data
447
12
Positioning
identifier
[Da.3]
Acceleration
time No.
0: [Pr.9] Acceleration time 0
00
0000H
6000+1000n
1: [Pr.25] Acceleration time 1
01
2: [Pr.26] Acceleration time 2
10
3: [Pr.27] Acceleration time 3
11
[Da.4]
Deceleration
time No.
0: [Pr.10] Deceleration time 0
00
1: [Pr.28] Deceleration time 1
01
2: [Pr.29] Deceleration time 2
10
3: [Pr.30] Deceleration time 3
11
[Da.6]
Positioning address/
movement amount
The setting value range differs according to the "[Da.2] Control method".
0
6006+1000n
6007+1000n
[Da.7]
Arc address
0
6008+1000n
6009+1000n
[Da.8]
Command speed
The setting value range differs depending on the "[Pr.1] Unit setting".
0
6004+1000n
6005+1000n
-1: Current speed (Speed set for previous
positioning data No.)
-1
[Da.9]
Dwell time/
JUMP
destination
positioning
data No.
Dwell time
The setting value range differs according to the "[Da.2] Control method".
0
6002+1000n
JUMP
destination
positioning
data No.
[Da.10]
M code/
Condition
data No./
Number of
LOOP to
LEND
repetitions/
Number of
pitches
M code
0
6001+1000n
Condition
data No.
Number of
LOOP to
LEND
repetitions
Axis to be
interpolated
[Da.20]
Axis to be
interpolated
No.1
0: Axis
1
selected
1: Axis
2
selected
2: Axis
3
selected
3: Axis
4
selected
4: Axis
5
selected
5: Axis
6
selected
6: Axis
7
selected
7: Axis
8
selected
8: Axis
9
selected
9: Axis 10 selected
A: Axis 11 selected
B: Axis 12 selected
C: Axis 13 selected
D: Axis 14 selected
E: Axis 15 selected
F: Axis 16 selected
0H
1H
2H
3H
4H
5H
6H
7H
8H
9H
AH
BH
CH
DH
EH
FH
0000H
71000+1000n
71001+1000n
[Da.21]
Axis to be
interpolated
No.2
[Da.22]
Axis to be
interpolated
No.3
Item
Setting value
Default
value
Buffer memory
address
Value set with the engineering tool
Value set with a program
H
b8
b12
b15
b4
b0
Convert into
hexadecimal
Setting value
[Da.2]
[Da.4]
[Da.3]
[Da.1]
[Da.21]
[Da.20]
Not used*
[Da.22]
b0
b4
b8
b12
b15
b16
b20
b24
b28
b31
*: Always "0" is set to the part not used.
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......