12 DATA USED FOR POSITIONING CONTROL
12.1 Types of Data
381
12
Setting items for block start data
The "block start data" must be set when carrying out "high-level positioning control". The setting items for the "block start data"
are shown below.
Up to 50 points of "block start data" can be set for each axis.
: Set as required ("
" when not required)
: Setting not required (The setting value is invalid. When the value is the default value or within the setting range, there is no
problem.)
Checking the block start data
[Da.11] to [Da.14] are checked with the following timing.
• When "Block start data" starts
Setting items for condition data
When carrying out "high-level positioning control" or using the JUMP instruction in the "major positioning control", the
"condition data" must be set as required. The setting items for the "condition data" are shown below.
Up to 10 "condition data" items can be set for each axis.
: Set as required ("
" when not required)
: Setting limited
: Setting not required (The setting value is invalid. When the value is the default value or within the setting range, there is no
problem.)
Checking the condition data
[Da.15] to [Da.19], [Da.23] to [Da.26] are checked with the following timing.
• When "Block start data" starts
• When "JUMP instruction" starts
Block start data
Block start
(Normal start)
Condition start
Wait start
Simultaneous start
Repeated start
(FOR loop)
Repeated start
(FOR condition)
[Da.11]
Shape (end/continue)
[Da.12]
Start data No.
[Da.13]
Special start
instruction
[Da.14]
Parameter
Condition data
Major positioning
control
High-level positioning control
Other than
JUMP
instruction
JUMP
instruction
Block
start
(Normal
start)
Condition
start
Wait
start
Simultaneous
start
Repeated
start
(FOR loop)
Repeated
start
(FOR
condition)
[Da.15]
Condition target
[Da.16]
Condition
operator
[Da.17]
Address
[Da.18]
Parameter 1
[Da.19]
Parameter 2
[Da.23]
Number of
simultaneously
starting axes
[Da.24]
Simultaneously
starting axis No.1
[Da.25]
Simultaneously
starting axis No.2
[Da.26]
Simultaneously
starting axis No.3
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......