![Mitsubishi Electric RD77MS16 User Manual Download Page 543](http://html.mh-extra.com/html/mitsubishi-electric/rd77ms16/rd77ms16_user-manual_1811857543.webp)
12 DATA USED FOR POSITIONING CONTROL
12.8 Control Data
541
12
[Cd.181] Forward run JOG start, [Cd.182] Reverse run JOG start
• When the JOG start signal is ON, JOG operation will be carried out at the "[Cd.17] JOG speed". When the JOG start signal
turns OFF, the operation will decelerate and stop.
• When inching movement amount is set, the designated movement amount is output for one operation cycle and then the
operation stops.
Fetch cycle: Operation cycle
■
Setting value
• Set with a decimal.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Cd.183] Execution prohibition flag
• If the execution prohibition flag is ON when the positioning start signal turns ON, positioning control does not start until the
execution prohibition flag turns OFF. Used with the "Pre-reading start function". (
Page 266 Pre-reading start function)
Fetch cycle: At start
■
Setting value
• Set with a decimal.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Setting
value
Forward run JOG start/Reverse run JOG start
1 : JOG started
Other than 1: JOG not started
K
Setting
value
Execution prohibition flag
1 : During execution prohibition
Other than 1: Not during execution prohibition
K
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......