14 TROUBLESHOOTING
14.5 List of Error Codes
607
14
1AB4H
Deceleration time 1
setting error
The setting value of the detailed parameter 2
"Deceleration time 1" is outside the setting range.
[Operation status at error occurrence]
When the PLC READY signal [Y0] is turned from
OFF to ON: The READY signal [X0] is not turned ON.
At start: The system does not start.
During operation: The system stops with the setting
(deceleration stop/sudden stop) of the detailed
parameter 2 sudden stop selection (stop group 3). (Note
that the deceleration stop only occurs during the
manual pulse generator operation.)
With the setting brought into the setting range, turn the
PLC READY signal [Y0] from OFF to ON.
1AB5H
Deceleration time 2
setting error
The setting value of the detailed parameter 2
"Deceleration time 2" is outside the setting range.
[Operation status at error occurrence]
When the PLC READY signal [Y0] is turned from
OFF to ON: The READY signal [X0] is not turned ON.
At start: The system does not start.
During operation: The system stops with the setting
(deceleration stop/sudden stop) of the detailed
parameter 2 sudden stop selection (stop group 3). (Note
that the deceleration stop only occurs during the
manual pulse generator operation.)
With the setting brought into the setting range, turn the
PLC READY signal [Y0] from OFF to ON.
1AB6H
Deceleration time 3
setting error
The setting value of the detailed parameter 2
"Deceleration time 3" is outside the setting range.
[Operation status at error occurrence]
When the PLC READY signal [Y0] is turned from
OFF to ON: The READY signal [X0] is not turned ON.
At start: The system does not start.
During operation: The system stops with the setting
(deceleration stop/sudden stop) of the detailed
parameter 2 sudden stop selection (stop group 3). (Note
that the deceleration stop only occurs during the
manual pulse generator operation.)
With the setting brought into the setting range, turn the
PLC READY signal [Y0] from OFF to ON.
1AB7H
JOG speed limit
value error
The setting value of the detailed parameter 2 "[Pr.31]
JOG speed limit value" is outside the setting range.
[Operation status at error occurrence]
When the PLC READY signal [Y0] is turned from
OFF to ON: The READY signal [X0] is not turned ON.
At start: The system does not start.
When the PLC READY signal [Y0] is not turned ON
after the setting value is corrected, turn the PLC
READY signal [Y0] from OFF to ON.
1AB8H
JOG speed limit
value error
The setting value of the detailed parameter 2 "[Pr.31]
JOG speed limit value" exceeds the "[Pr.8] Speed limit
value".
[Operation status at error occurrence]
When the PLC READY signal [Y0] is turned from
OFF to ON: The READY signal [X0] is not turned ON.
At start: The system does not start.
When the PLC READY signal [Y0] is not turned ON
after the setting value is set to equal to or less than the
"[Pr.8] Speed limit value", turn the PLC READY signal
[Y0] from OFF to ON.
1AB9H
JOG speed limit
value error
The setting value of the detailed parameter 2 "[Pr.31]
JOG speed limit value" is smaller than the "[Pr.7] Bias
speed at start".
[Operation status at error occurrence]
When the PLC READY signal [Y0] is turned from
OFF to ON: The READY signal [X0] is not turned ON.
At start: The system does not start.
When the PLC READY signal [Y0] is not turned ON
after the setting value is set to equal to or more than
the "[Pr.7] Bias speed at start", turn the PLC READY
signal [Y0] from OFF to ON.
1ABAH
Manual pulse
generator speed limit
value error
The setting value of the detailed parameter 2 "Manual
pulse generator speed limit value" is outside the setting
range.
[Operation status at error occurrence]
At the power on or when the PLC READY signal [Y0] is
turned from OFF to ON: The READY signal [X0] is not
turned ON.
At start: The system does not operate.
Correct the setting value and turn the PLC READY
signal [Y0] from OFF to ON.
Error code
(Hexadecimal)
Error name
Error details and causes
Remedy
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......