418
12 DATA USED FOR POSITIONING CONTROL
12.3 Basic Setting
Detailed parameters1
n: Axis No. - 1
*1
The setting is not available in "[Pr.119] STOP signal selection".
Item
Setting value, setting range
Default value
Buffer memory
address
Value set with the engineering tool
Value set with a program
[Pr.11]
Backlash compensation
amount
The setting value range differs according to the "[Pr.1] Unit setting".
0
17+150n
[Pr.12]
Software stroke limit
upper limit value
2147483647
18+150n
19+150n
[Pr.13]
Software stroke limit
lower limit value
-2147483648
20+150n
21+150n
[Pr.14]
Software stroke limit
selection
0: Apply software stroke limit on current feed value
0
0
22+150n
1: Apply software stroke limit on machine feed
value
1
[Pr.15]
Software stroke limit
valid/invalid setting
0: Software stroke limit valid during JOG
operation, inching operation and manual pulse
generator operation
0
0
23+150n
1: Software stroke limit invalid during JOG
operation, inching operation and manual pulse
generator operation
1
[Pr.16]
Command in-position
width
The setting value range differs depending on the "[Pr.1] Unit setting".
100
24+150n
25+150n
[Pr.17]
Torque limit setting value
0.1 to 1000.0 (%)
1 to 10000 (
0.1%)
3000
26+150n
[Pr.18]
M code ON signal output
timing
0: WITH
mode
0
0
27+150n
1: AFTER
mode
1
[Pr.19]
Speed switching mode
0: Standard speed switching mode
0
0
28+150n
1: Front-loading speed switching mode
1
[Pr.20]
Interpolation speed
designation method
0: Composite
speed
0
0
29+150n
1: Reference axis speed
1
[Pr.21]
Current feed value
during speed control
0: Do not update current feed value
0
0
30+150n
1: Update current feed value
1
2: Clear current feed value to zero
2
[Pr.22]
Input signal logic
selection
b0
Lower limit
0: Negative
logic
1: Positive
logic
0
31+150n
b1
Upper limit
b2
Not used
b3
Stop signal
b4
Not used
b5
Not used
b6
Near-point dog signal
b7
to b15
Not used
[Pr.81]
Speed-position function
selection
0: Speed-position switching control (INC mode)
0
0
34+150n
2: Speed-position switching control (ABS mode)
2
[Pr.116]
FLS signal selection
b0 to b3: Input type
0 (0000H): Simple Motion module
1 (0001H): Servo amplifier
2 (0002H): Buffer memory
15 (000FH): Invalid
b4 to b11: Input terminal
RD77MS: 01H to 0AH
RD77MS4/8/16: 01H to 14H
b12 to b15: Not used
0001H
116+150n
[Pr.117]
RLS signal selection
0001H
117+150n
[Pr.118]
DOG signal selection
0001H
118+150n
[Pr.119]
STOP signal selection
0002H
119+150n
b0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Always "0"
is set to
the part
not used.
b15 to b12 b11 to b8 b7 to b4
b3 to b0
Always "0" is
set to the part
not used.
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......