340
9 COMMON FUNCTIONS
9.10 Optional Data Monitor Function
9.10
Optional Data Monitor Function
This function is used to store the data (refer to following table) up to four points per axis to the buffer memory and monitor
them.
Data that can be set
: Possible,
: Not possible ("0" is stored.)
*1
The motor speed that took the average every 227 [ms].
Use the servo amplifiers of version compatible with the monitor of motor speed.
Always "0" if the monitor is executed for the servo amplifier which does not support this function.
*2
The data set to "Droop pulse monitor selection for controller display" of "Fully closed loop function selection 3 (PE10)" is monitored.
*3
It can be monitored when using the linear servo motors.
*4
It can be monitored when using the fully closed control.
*5
It can be monitored when using the synchronous encoder via servo amplifier.
Refer to each servo amplifier instruction manual for details of the data monitored.
Data type
Unit
Used point
Monitoring possibility
MR-J3(W)-B
MR-J4(W)-B
MR-JE-B
1
Effective load ratio
[%]
1 word
2
Regenerative load ratio
[%]
3
Peak load factor
[%]
4
Load inertia moment ratio
[
0.1]
5
Model loop gain
[rad/s]
6
Bus voltage
[V]
7
Servomotor rotation speed
[r/min]
8
Encoder multiple revolution counter
[rev]
9
Module power consumption
[W]
10
Instantaneous torque
[
0.1%]
12
Servomotor thermistor temperature
[
]
13
Equivalent disturbance torque
[
0.1%]
14
Overload alarm margin
[
0.1%]
15
Error excessive alarm margin
[
16 pulses]
16
Settling time
[ms]
17
Overshoot amount
[pulse]
20
Position feedback
[pulse]
2 words
21
Encoder single revolution position
[pulse]
22
Selection droop pulse
[pulse]
23
Module integral power consumption
[Wh]
24
Load side encoder information 1
[pulse]
25
Load side encoder information 2
26
Z-phase counter
[pulse]
27
Servomotor side/load-side position deviation
[pulse]
28
Servomotor side/load-side speed deviation
[
0.01 r/min]
30
Module power consumption (2 words)
[W]
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......