516
12 DATA USED FOR POSITIONING CONTROL
12.8 Control Data
[Cd.16] Inching movement amount
• Use this data item to set the amount of movement by inching.
• The machine performs a JOG operation if "0" is set.
• Set a value within the following range:
Fetch cycle: At start
■
Setting value
• Set with a decimal.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Pr.1] Unit setting
mm (
10
-1
m)
inch (
10
-5
inch)
degree (
10
-5
degree)
pulse (pulse)
Setting range
0 to 65535
0 to 65535
0 to 65535
0 to 65535
Conversion into an integer value
[Cd.16] Inching movement amount
×
10
m
Unit conversion table ([Cd.16])
m
μ
m
inch
1
5
5
degree
0
pulse
Unit
R
Setting value
(Decimal)
Actual value
Example: When the "[Cd.16] Inching
movement amount" is set as
"1.0
μ
m", the buffer memory
stores "10".