![Mitsubishi Electric RD77MS16 User Manual Download Page 412](http://html.mh-extra.com/html/mitsubishi-electric/rd77ms16/rd77ms16_user-manual_1811857412.webp)
410
12 DATA USED FOR POSITIONING CONTROL
12.3 Basic Setting
■
PULSE/SIGN
[Pr.82] Forced stop valid/invalid selection
Set the forced stop valid/invalid.
All axes of the servo amplifier are made to batch forced stop when the forced stop input signal is turned on. The error "Servo
READY signal OFF during operation" (error code: 1902H) does not occur if the forced input signal is turned on during
operation.
• If the setting is other than 0 and 1, the error "Forced stop valid/invalid setting error" (error code: 1B71H)
occurs.
• The "[Md.50] Forced stop input" is stored "1" by setting "Forced stop valid/invalid selection" to invalid.
[Pr.89] Manual pulse generator/Incremental synchronous encoder input type selection
Set the input type from the manual pulse generator/incremental synchronous encoder.
Refer to the following for details.
MELSEC iQ-R Simple Motion Module User's Manual (Startup)
The "Manual pulse generator/Incremental synchronous encoder input type selection" is included in common
parameters. However, it will be valid at the leading edge (OFF to ON) of the PLC READY signal [Y0].
[Pr.151] Manual pulse generator/Incremental synchronous encoder input logic selection
Positive logic
Negative logic
Forward run and reverse run are controlled with the ON/OFF of the direction
sign (SIGN).
The motor will forward run when the direction sign is HIGH.
The motor will reverse run when the direction sign is LOW.
Forward run and reverse run are controlled with the ON/OFF of the direction
sign (SIGN).
The motor will forward run when the direction sign is LOW.
The motor will reverse run when the direction sign is HIGH.
Forced stop valid/invalid selection
Setting value
Valid (Forced stop is used.)
0
Invalid (Forced stop is not used.)
1
Manual pulse generator/Incremental synchronous encoder input type selection
Setting value
Differential output type
0
Voltage output/open collector type
1
PULSE
SIGN
Forward run
Reverse run
Move in
+ direction
Move in
- direction
PULSE
SIGN
Forward run
Reverse run
Move in
+ direction
Move in
- direction
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......