486
12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
[Md.33] Target speed
• During operation with positioning data: The actual target speed, considering the override and speed limit value, etc., is
stored. "0" is stored when positioning is completed.
• During interpolation of position control: The composite speed or reference axis speed is stored in the reference axis
address, and "0" is stored in the interpolation axis address.
• During interpolation of speed control: The target speeds of each axis are stored in the monitor of the reference axis and
interpolation axis.
• During JOG operation: The actual target speed, considering the JOG speed limit value for the JOG speed, is stored.
• During manual pulse generator operation: "0" is stored.
Refresh cycle: Immediate
The target speed is when an override is made to the command speed.
When the speed limit value is overridden, the target speed is restricted to the speed limit value. The target
speed changes every time data is switched, but does not change in an acceleration/deceleration state inside
each piece of data (changes with the speed change because the target speed changes.)
■
Reading the monitor value
• Monitoring is carried out with a hexadecimal display.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Actual value
A
B
C
D
A
B
C
D
E
F
G
H
E
R
F
G
H
Sorting
Unit conversion
(Low-order buffer memory)
(High-order buffer memory)
Low-order buffer memory
b15
b12
b4
b0
b8
E
F
G
H
High-order buffer memory
b31
b28
b20
b16
b24
A
B
C
D
[Md.33] Target speed
R
×
10
m
Unit conversion table ([Md.34])
m
-1
μ
m
-5
inch
-5
degree
0
pulse
Unit
Unit conversion table ([Md.33])
m
-2
mm/min
-3
inch/min
-3
*
degree/min
0
pulse/s
Unit
Monitor
value
Decimal integer
value
[Md.34] Movement amount after
near-point dog ON
Converted from
hexadecimal to decimal
*: When "[Pr.83] Speed control
10
×
multiplier setting for
degree axis" is valid: "-2"
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......