14 TROUBLESHOOTING
14.4 List of Warning Codes
583
14
0938H
Outside mark
detection data axis
No. setting range
When the mark detection data type setting is not
"Optional 2 word buffer memory", the mark detection
data type setting is outside the range.
[Operation status at warning occurrence]
The setting number of which the mark detection setting
parameter is outside the range is invalid.
Set a value within the setting range.
0939H
Outside mark
detection data buffer
memory No. setting
range
When the mark detection data type setting is "Optional 2
word buffer memory", the mark detection data buffer
memory No. is outside the range or odd number.
[Operation status at warning occurrence]
The setting number of which the mark detection setting
parameter is outside the range is invalid.
Set a value with an even number within the setting
range.
093AH
Outside maximum
number of control
axes
The common parameter "[Pr.152] Maximum number of
control axes" exceeds the number of control axes of
Simple Motion module.
[Operation status at warning occurrence]
Controlled as "0: No setting".
Correct the setting value.
093BH
Outside control axis
setting
"[Pr.100] Connected device" is set to the axis that
exceeded the "[Pr.152] Maximum number of control
axes".
[Operation status at warning occurrence]
The communication with the connected device is not
executed.
Correct the "[Pr.152] Maximum number of control
axes" or "[Pr.100] Connected device".
093CH
Home position return
data incorrect
• The backup data for absolute position restoration is
illegal.
• The home position return has never been executed
after the system start.
• The home position return is started, but not completed
correctly.
• "Absolute position erased" in the driver is detected.
• "Rotation direction selection (PA14)" of the servo
parameter has been changed.
[Operation status at warning occurrence]
The operation continues.
Execute home position return.
093EH
SSCNET
communication error
Data received from servo amplifier is in error.
[Operation status at warning occurrence]
The operation continues.
• Check the SSCNET
cable.
• Check the servomotor and encoder cable.
• Take measures against noise.
• Check whether the rotation direction selection/travel
direction selection (PA14) is set "0
1" or "1
0"
in the user program or the engineering tool.
0980H
Speed change during
deceleration
The speed change request is issued during deceleration
stop with JOG start signal OFF.
[Operation status at warning occurrence]
The speed change is not carried out.
Do not carry out the JOG speed change during
deceleration with the JOG start signal OFF.
0981H
JOG speed limit
value
The JOG speed
exceeds the JOG speed limit value at
start.
[Operation status at warning occurrence]
• When the speed exceeds the JOG speed limit, the
JOG operation is carried out with the JOG speed limit
value.
• While the speed is limited by the JOG speed limit
value, the "[Md.39] In speed limit flag" is turned ON.
Set a value within the setting range.
0982H
JOG speed limit
value
The new speed value
exceeds the JOG speed limit
value when the speed is changed during operation.
[Operation status at warning occurrence]
• When the speed exceeds the JOG speed limit, the
JOG operation is carried out with the JOG speed limit
value.
• While the speed is limited by the JOG speed limit
value, the "[Md.39] In speed limit flag" is turned ON.
Set a value within the setting range.
0988H
Outside manual
pulse generator input
magnification range
The manual pulse generator 1 pulse input magnification
is set to 0, 10001 or more, or negative value.
[Operation status at warning occurrence]
• When input magnification is set at 10001 or more, or
negative value: Re-set to 10000.
• When input magnification is set at 0: Re-set to 1.
Set the manual pulse generator 1 pulse input
magnification to within the setting range.
Warning code
(Hexadecimal)
Warning name
Error details and causes
Remedy
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......