8 CONTROL SUB FUNCTIONS
8.9 Other Functions
291
8
Setting method
To use the "command in-position function", set the required value in the parameter shown in the following table, and write it to
the Simple Motion module.
The set details are validated at the rising edge (OFF
ON) of the PLC READY signal [Y0].
Refer to the following for the setting details.
Confirming the command in-position flag
The "command in-position flag" is stored in the following buffer memory.
n: Axis No. - 1
Refer to the following for information on the storage details.
• Parameters are set for each axis.
• It is recommended that the parameters be set whenever possible with the engineering tool. Execution by a
program uses many programs and devices. The execution becomes complicated, and the scan times will
increase.
Setting item
Setting
value
Setting details
Factory-set initial
value
[Pr.16]
Command in-position width
Turn ON the command in-position flag, and set the remaining distance
to the stop position of the position control.
100
Monitor item
Monitor
value
Storage details
Buffer memory address
[Md.31]
Status
The command in-position flag is stored in the "b2" position.
2417+100n
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......