11 SPECIFICATIONS OF I/O SIGNALS WITH CPU MODULES
11.2 Details of Input Signals
359
11
11.2
Details of Input Signals
The ON/OFF timing and conditions of the input signals are shown below.
*1
The BUSY signal, whose axis number exceeds the number of controlled axes, cannot be used.
The BUSY signal turns ON even when position control of movement amount 0 is executed. However, since
the ON time is short, the ON status may not to be detected in the program.
Device
No.
Signal name
Details
X0
READY
ON: READY
OFF: Not READY/Watch dog
timer error
• When the PLC READY signal [Y0] turns from OFF to ON, the parameter setting range is
checked. If no error is found, this signal turns ON.
• When the PLC READY signal [Y0] turns OFF, this signal turns OFF.
• When watch dog timer error occurs, this signal turns OFF.
• This signal is used for interlock in a program, etc.
X1
Synchronization
flag
OFF: Module access
disabled
ON: Module
access
enabled
• After the CPU module is turned ON or the CPU module is reset, this signal turns ON if the
access from the CPU module to the Simple Motion module is possible.
• When "Asynchronous" is selected in the module synchronization setting of the CPU
module, this signal can be used as interlock for the access from a program to the Simple
Motion module.
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
Axis 1
Axis 2
Axis 3
Axis 4
Axis 5
Axis 6
Axis 7
Axis 8
Axis 9
Axis 10
Axis 11
Axis 12
Axis 13
Axis 14
Axis 15
Axis 16
BUSY
OFF: Not BUSY
ON: BUSY
• This signal turns ON at the start of positioning, home position return or JOG operation. It
turns OFF when the "[Da.9] Dwell time/JUMP destination positioning data No." has
passed after positioning stops. (This signal remains ON during positioning.)
• This signal turns OFF when the positioning is stopped with step operation.
• During manual pulse generator operation, this signal turns ON while the "[Cd.21] Manual
pulse generator enable flag" is ON.
• This signal turns OFF at error completion or positioning stop.
PLC READY signal [Y0]
ON
OFF
READY signal [X0]
ON
OFF
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......