12 DATA USED FOR POSITIONING CONTROL
12.2 List of Buffer Memory Addresses
389
12
Positioning
parameters
Detailed
parameters 1
[Pr.22]
Input signal logic selection
31+150n
[Pr.81]
Speed-position function selection
34+150n
[Pr.116]
FLS signal selection
116+150n
[Pr.117]
RLS signal selection
117+150n
[Pr.118]
DOG signal selection
118+150n
[Pr.119]
STOP signal selection
119+150n
Detailed
parameters 2
[Pr.25]
Acceleration time 1
36+150n
37+150n
[Pr.26]
Acceleration time 2
38+150n
39+150n
[Pr.27]
Acceleration time 3
40+150n
41+150n
[Pr.28]
Deceleration time 1
42+150n
43+150n
[Pr.29]
Deceleration time 2
44+150n
45+150n
[Pr.30]
Deceleration time 3
46+150n
47+150n
[Pr.31]
JOG speed limit value
48+150n
49+150n
[Pr.32]
JOG operation acceleration time selection
50+150n
[Pr.33]
JOG operation deceleration time selection
51+150n
[Pr.34]
Acceleration/deceleration process selection
52+150n
[Pr.35]
S-curve ratio
53+150n
[Pr.36]
Sudden stop deceleration time
54+150n
55+150n
[Pr.37]
Stop group 1 sudden stop selection
56+150n
[Pr.38]
Stop group 2 sudden stop selection
57+150n
[Pr.39]
Stop group 3 sudden stop selection
58+150n
[Pr.40]
Positioning complete signal output time
59+150n
[Pr.41]
Allowable circular interpolation error width
60+150n
61+150n
[Pr.42]
External command function selection
62+150n
[Pr.83]
Speed control 10
multiplier setting for degree axis
63+150n
[Pr.84]
Restart allowable range when servo OFF to ON
64+150n
65+150n
[Pr.90]
Operation setting for speed-torque control mode
68+150n
[Pr.95]
External command signal selection
69+150n
[Pr.122]
Manual pulse generator speed limit mode
121+150n
[Pr.123]
Manual pulse generator speed limit value
122+150n
123+150n
Home
position
return
parameters
Home position
return basic
parameters
[Pr.43]
Home position return method
70+150n
[Pr.44]
Home position return direction
71+150n
[Pr.45]
Home position address
72+150n
73+150n
[Pr.46]
Home position return speed
74+150n
75+150n
[Pr.47]
Creep speed
76+150n
77+150n
[Pr.48]
Home position return retry
78+150n
Memory area
Item
Buffer memory address
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......