436
11 OPTIONS AND PERIPHERAL EQUIPMENT
11.17 External dynamic brake
Connection example
■
200 V class
*1 Terminals 13 and 14 are normally open contact outputs. If the external dynamic brake is seized, terminals 13 and 14 will open.
Therefore, configure up an external sequence to prevent servo-on.
*2 Assign DB (Dynamic brake interlock) in [Pr. PD07] to [Pr. PD09].
*3 For the power supply specifications, refer to the following.
Page 30 Servo amplifier standard specifications
*4 Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop deceleration to
shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, delay the time to turn off the magnetic
contactor.
*5 Turn off EM2 when the main power circuit power supply is off.
*6 The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be
configured by one.
*7 Between P3 and P4 is connected by default. When using the power factor improving DC reactor, remove the short bar between P3 and
P4. Additionally, a power factor improving DC reactor and power factor improving AC reactor cannot be used together.
Page 407 Power factor improving DC reactors
*8 The external dynamic brake cannot be used for compliance with SEMI-F47 standard. Do not assign DB (Dynamic brake interlock) in [Pr.
PD07] to [Pr. PD09]. Failure to do so will cause the servo amplifier to become servo-off when an instantaneous power failure occurs.
*9 Install an overcurrent protection device (molded-case circuit breaker, fuse, or others) to protect the branch circuit.
Page 404 Molded-case circuit breakers, fuses, magnetic contactors
Page 435 Selection of external dynamic brake
Emergency
stop switch
L11
L21
U
V
W
U
V
W
E
M
Servo amplifier
Servo motor
L3
L2
L1
Power
supply
*3
13
U
14
V
W
External dynamic brake
a
b
*1
ALM
15
DB
*2*8
DOCOM
3
CN3
RA2
MCCB
Operation ready
MC
ALM
RA1
OFF
ON
MC
SK
RA1
RA2
MC
*4
Dynamick brake
interlock
Main circuit
power supply
*5
24 V DC
*6
5
DICOM
10
EM2
20
DICOM
CN3
24 V DC
*6
P3
P4
*7
*9
*9