11 OPTIONS AND PERIPHERAL EQUIPMENT
11.11 Power factor improving DC reactors
411
11
*1 Use this for grounding.
*2 When using the power factor improving DC reactor, remove the short bar between P3 and P4.
*3 Selection conditions of wire size are as follows.
Wire type: 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: Single wire set in midair
Servo amplifier
Power factor
improving
DC reactor
Dimensions [mm]
Terminal
size
Mass
[kg]
Wire [mm
2
W
W1
H
D
D1
D2
D3
d
MR-J4-700GF4(-RJ)
FR-HEL-H15K
105
75
152
125
115
95
62
M5
M6
5.0
5.5 (AWG 10)
MR-J4-11KGF4(-RJ)
8 (AWG 8)
MR-J4-15KGF4(-RJ)
FR-HEL-H22K
133
90
178
120
95
75
53
M5
M6
6.0
8 (AWG 8)
MR-J4-22KGF4(-RJ)
FR-HEL-H30K
133
90
178
120
100
80
56
M5
M6
6.5
14 (AWG 6)
H ± 2.5
W1
W ± 2.5
D2
D1 ± 1
P
P1
D or less
(D3)
4-d mounting hole
*1
6
*2
Servo amplifier
P3
P4
FR-HEL-H
5 m or less