274
7 SPECIAL ADJUSTMENT FUNCTIONS
7.4 Compliance with SEMI-F47 standard
Calculation of tolerance against instantaneous power failure
The following shows tolerance against instantaneous power failure when instantaneous power failure voltage is "rated voltage
50%" and instantaneous power failure time is 200 ms.
Instantaneous maximum output means power which servo amplifier can output in maximum torque at rated speed. You can
examine margins to compare the values of following conditions and instantaneous maximum output.
Even if driving at maximum torque with low speed in actual operation, the motor will not drive with the maximum output. This
can be handled as a margin.
The following shows the conditions of tolerance against instantaneous power failure
■
Delta connection
For the 3-phase (L1/L2/L3) delta connection, an instantaneous power failure occurs in the voltage between a pair of lines (e.g.
between L1 and L2) among voltages between three pairs of lines (between L1 and L2, L2 and L3, or L3 and L1).
■
Star connection
For the 3-phase (L1/L2/L3/neutral point N) star connection, an instantaneous power failure occurs in the voltage between a
pair of lines (e.g. between L1 and N) among voltages at six locations, between three pairs of lines (between L1 and L2, L2 and
L3, or L3 and L1) and between one of the lines and the neutral point (between L1 and N, L2 and N, or L3 and N).
Servo amplifier
Instantaneous maximum output [W]
Tolerance against instantaneous power
failure [W] (voltage drop between lines)
MR-J4-10GF(-RJ)
350
250
MR-J4-20GF(-RJ)
700
420
MR-J4-40GF(-RJ)
1400
630
MR-J4-60GF(-RJ)
2100
410
MR-J4-70GF(-RJ)
2625
1150
MR-J4-100GF(-RJ)
3000
1190
MR-J4-200GF(-RJ)
5400
2040
MR-J4-350GF(-RJ)
10500
2600
MR-J4-500GF(-RJ)
15000
4100
MR-J4-700GF(-RJ)
21000
5900
MR-J4-11KGF(-RJ)
40000
2600
MR-J4-15KGF(-RJ)
50000
3500
MR-J4-22KGF(-RJ)
56000
4300
MR-J4-60GF4(-RJ)
1900
190
MR-J4-100GF4(-RJ)
3500
200
MR-J4-200GF4(-RJ)
5400
350
MR-J4-350GF4(-RJ)
10500
730
MR-J4-500GF4(-RJ)
15000
890
MR-J4-700GF4(-RJ)
21000
1500
MR-J4-11KGF4(-RJ)
40000
2400
MR-J4-15KGF4(-RJ)
50000
3200
MR-J4-22KGF4(-RJ)
56000
4200
Summary of Contents for MELSERVO-J4 series