278
7 SPECIAL ADJUSTMENT FUNCTIONS
7.6 Lost motion compensation function
■
Adjusting the lost motion compensation non-sensitive band
When the lost motion is compensated twice around a quadrant change point, set [Pr. PE50 Lost motion compensation non-
sensitive band]. Increase the setting value so that the lost motion is not compensated twice. Setting [Pr. PE50] may change
the compensation timing. Adjust the lost motion compensation timing in the following section.
Page 277 Adjusting the lost motion compensation timing
Before timing delay compensation
After timing delay compensation
Compensation
Travel
direction