122
3 SIGNALS AND WIRING
3.9 Servo motor with an electromagnetic brake
■
Alarm occurrence
• When the forced stop deceleration function is enabled
*1 The model speed command is a speed command generated in the servo amplifier for forced stop deceleration of the servo motor.
Controller command is
not received.
Alarm occurrence
Alarm No.
No alarm
Model speed command 0
and equal to or less than
zero speed
*1
MBR
(Electromagnetic
brake interlock)
ON
OFF
ON (no alarm)
OFF (alarm)
Base circuit
(Energy supply to
the servo motor)
ON
OFF
Servo amplifier
display
0 r/min
Servo motor speed
ALM (Malfunction)
Tb [Pr. PC02 Electromagnetic
brake sequence output]
Operation delay time
of the electromagnetic
brake
ON
ON
OFF
Release
Activate
OFF
Electromagnetic
brake
Ready-on command
(from controller)
Servo-on command
(from controller)