70
1 FUNCTIONS AND CONFIGURATION
1.8 Configuration including peripheral equipment
■
MR-J4-500GF4(-RJ)
The diagram shows MR-J4-500GF4-RJ.
*1 The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used. When not
using the power factor improving DC reactor, short P3 and P4.
*2 Refer to the following for the power supply specification.
Page 30 Servo amplifier standard specifications
*3 Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop deceleration to
shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, slow the time to turn off the magnetic
contactor.
*4 This is for MR-J4-_GF4-RJ servo amplifier. MR-J4-_GF4 servo amplifier does not have CN2L connector. When using MR-J4-_GF4-RJ
servo amplifier in the linear servo system or in the fully closed loop system, connect an external encoder to this connector. Refer to the
following and "Linear Encoder Instruction Manual" for the compatible external encoders.
*5 When using the regenerative option, refer to the following.
P+
C
L21
L11
W
V
U
L1
L2
L3
P3
P4
CN4
R S T
CN5
MR Configurator2
CN3
CN8
CN1A
CN1B
CN2L
*4
Line noise
filter
(FR-BSF01)
Regenerative
option
*5
Servo motor
Personal
computer
Magnetic
contactor
*3
*1
(MC)
Power factor
improving DC
reactor
(FR-HEL-H)
Junction
terminal
block
Safety relay or
MR-J3-D05
safety logic unit
Battery
Molded-case
circuit breaker
(MCCB)
Power supply
*2
Servo system
controller or
servo amplifier
Servo system
controller or
servo amplifier
Summary of Contents for MELSERVO-J4 series
Page 2: ......
Page 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Page 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Page 645: ......