402
11 OPTIONS AND PERIPHERAL EQUIPMENT
11.9 Selection example of wires
■
400 V class
*1 Alphabets in the table indicate crimping tools. For crimp terminals and applicable tools, refer to the following.
Page 403 Selection example of crimp terminals
*2 To connect these models to a terminal block, be sure to use the screws that come with the terminal block.
*3 The wire size shows applicable size of the servo amplifier connector and terminal block. For wires connecting to the servo motor, refer to
each servo motor instruction manual.
*4 Be sure to use the size of 2 mm
2
when corresponding to IEC/EN/UL/CSA standard.
*5 This is for connecting to the linear servo motor with natural cooling method.
*6 This is for connecting to the linear servo motor with liquid cooling method.
Use wires (5)) of the following sizes with the power regeneration converter (FR-RC-H).
■
100 V class
*1 The wire size shows applicable size of the servo amplifier connector and terminal block. For wires connecting to the servo motor, refer to
each servo motor instruction manual.
*2 Be sure to use the size of 2 mm
2
when corresponding to IEC/EN/UL/CSA standard.
Servo amplifier
Wire [mm
2
]
1) L1/L2/L3/
2) L11/L21
3) P+/C
4) U/V/W/
MR-J4-60GF4(-RJ)
MR-J4-100GF4(-RJ)
2 (AWG 14)
1.25 to 2
(AWG 16 to 14)
2 (AWG 14)
AWG 16 to 14
MR-J4-200GF4(-RJ)
MR-J4-350GF4(-RJ)
MR-J4-500GF4(-RJ)
2 (AWG 14): b
1.25 (AWG 16): a
2 (AWG 14): c
2 (AWG 14): b
3.5 (AWG 12): a
MR-J4-700GF4(-RJ)
3.5 (AWG 12): a
5.5 (AWG 10): a
5.5 (AWG 10): d
1.25 (AWG 16): b
2 (AWG 14): b
2 (AWG 14): f
8 (AWG 8): g
MR-J4-15KGF4(-RJ)
8 (AWG 8): g
3.5 (AWG 12): d
MR-J4-22KGF4(-RJ)
14 (AWG 6): i
3.5 (AWG 12): e
8 (AWG 8): h
14 (AWG 6): i
Model
Wire [mm
2
]
FR-RC-H15K
14 (AWG 6)
FR-RC-H30K
FR-RC-H55K
Servo amplifier
Wire [mm
2
]
1) L1/L2/
2) L11/L21
3) P+/C
4) U/V/W/
MR-J4-10GF1(-RJ)
2 (AWG 14)
1.25 to 2
(AWG 16 to 14)
2 (AWG 14)
AWG 18 to 14
MR-J4-20GF1(-RJ)
MR-J4-40GF1(-RJ)