398
11 OPTIONS AND PERIPHERAL EQUIPMENT
11.8 Battery
Assembly of the case
After all MR-BAT6V1 batteries are mounted, fit the cover and insert screws into the two holes and tighten them. Tightening
torque is 0.71 N•m.
When assembling the case, be careful not to get the lead wires caught in the fitting parts or the screwing parts.
Precautions for removal of battery
The connector attached to the MR-BAT6V1 battery has the lock release lever. When removing the connector, pull out the
connector while pressing the lock release lever.
• Battery cable removal
CAUTION
• Pulling out the connector of the MR-BT6V1CBL and the MR-BT6V2CBL without the lock release lever pressed may damage the CN4 connector of the servo
amplifier or the connector of the MR-BT6V1CBL or MR-BT6V2CBL.
Screws
While pressing the lock release lever,
pull out the connector.