APPX
Appendix 4 Compliance with global standards
579
A
The following shows representative configuration examples to conform to the IEC/EN/UL/CSA standards.
The connectors described by rectangles are safely separated from the main circuits described by circles.
The connected motors will be limited as follows.
• HG/HF/HC/HA series servo motors (Mfg.: Mitsubishi Electric)
• Using a servo motor complied with IEC 60034-1 and Mitsubishi Electric encoder (OBA, OSA)
3-phase input for MR-J4 1-axis servo amplifier
*1 When the wire sizes of L1 and L11 are the same, MCCB or fuse is not required.
*2 Please use a thermal sensor, etc. for thermal protection of the servo motor.
*3 For 400 V class, a step-down transformer is not required.
1-phase input for MR-J4 1-axis servo amplifier
*1 When the wire sizes of L1 and L11 are the same, MCCB or fuse is not required.
*2 When using a 100 V class servo amplifier, step down the power supply voltage to 100 V and connect the main circuit power supply lines
to L1 and L2. For 1-phase 200 V AC servo amplifiers, connect the lines to L1 and L3.
*3 Please use a thermal sensor, etc. for thermal protection of the servo motor.
Main circuit 48 V DC input for MR-J4 1-axis servo amplifier
*1 Please use a thermal sensor, etc. for thermal protection of the servo motor.
MCCB
or fuse
Controller
STO
Encoder cable
(3-phase
230 V AC)
Power
supply
(3-phase
400 V AC)
Transformer
(star-connected)
*3
MCCB
or fuse
*1
PE
L11
L21
MC
Servo amplifier
Cabinet side
Machine side
Encoder
Servo motor
L1
C
P+
D
N-
U/V/W/PE
CN2
CN1
CN8
L2 L3
To protective equipment
(Thermal signal)
*2
MCCB
or fuse
Controller
STO
Encoder cable
(1-phase
230 V AC)
Power
supply
(3-phase
400 V AC)
Transformer
(star-connected)
MCCB
or fuse
*1
PE
L11
L21
MC
Servo amplifier
Cabinet side
Machine side
Encoder
Servo motor
L1
C
P+
D
N-
U/V/W/PE
CN2
CN1
CN8
L2 L3
*2
*2
To protective equipment
(Thermal signal)
*3
Controller
Encoder cable
CNP1
48 V DC
24 V DC
Servo amplifier
Encoder
Servo motor
CN2
CN1
Cabinet side
Machine side
To protective equipment
(Thermal signal)
*1
0
PM
24