2 INSTALLATION
2.1 Installation direction and clearances
77
2
2.1
Installation direction and clearances
Installation clearances of the servo amplifier
■
Installation of one servo amplifier
*1 For 11 kW to 22 kW servo amplifiers, the clearance between the bottom and ground will be 120 mm or more.
*2 When mounting MR-J4-500GF(-RJ), maintain a minimum clearance of 25 mm on the left side.
CAUTION
• The equipment must be installed in the specified direction. Otherwise, it may cause a malfunction.
• Leave specified clearances between the servo amplifier and the cabinet walls or other equipment. Otherwise, it may cause a malfunction.
40 mm or more
10 mm
or more
10 mm
or more
*2
40 mm
or more
*1
Servo amplifier
Cabinet
Cabinet
Wiring allowance
80 mm or more
Top
Bottom