8 TROUBLESHOOTING
8.2 Alarm list
283
8
27
Initial magnetic pole detection
error
27.1
Initial magnetic pole detection - Abnormal termination
DB
27.2
Initial magnetic pole detection - Time out error
DB
27.3
Initial magnetic pole detection - Limit switch error
DB
27.4
Initial magnetic pole detection - Estimated error
DB
27.5
Initial magnetic pole detection - Position deviation
error
DB
27.6
Initial magnetic pole detection - Speed deviation error
DB
27.7
Initial magnetic pole detection - Current error
DB
28
Linear encoder error 2
28.1
Linear encoder - Environment error
EDB
2A
Linear encoder error 1
2A.1
Linear encoder error 1-1
EDB
2A.2
Linear encoder error 1-2
EDB
2A.3
Linear encoder error 1-3
EDB
2A.4
Linear encoder error 1-4
EDB
2A.5
Linear encoder error 1-5
EDB
2A.6
Linear encoder error 1-6
EDB
2A.7
Linear encoder error 1-7
EDB
2A.8
Linear encoder error 1-8
EDB
2B
Encoder counter error
2B.1
Encoder counter error 1
EDB
2B.2
Encoder counter error 2
EDB
30
Regenerative error
30.1
Regeneration heat error
DB
30.2
Regeneration signal error
DB
30.3
Regeneration feedback signal error
DB
31
Overspeed
31.1
Abnormal motor speed
SD
32
Overcurrent
32.1
Overcurrent detected at hardware detection circuit
(during operation)
DB
32.2
Overcurrent detected at software detection function
(during operation)
DB
32.3
Overcurrent detected at hardware detection circuit
(during a stop)
DB
32.4
Overcurrent detected at software detection function
(during a stop)
DB
33
Overvoltage
33.1
Main circuit voltage error
EDB
34
SSCNET receive error 1
34.1
SSCNET receive data error
SD
34.2
SSCNET connector connection error
SD
34.3
SSCNET communication data error
SD
34.4
Hardware error signal detection
SD
34.5
SSCNET receive data error (safety observation
function)
SD
34.6
SSCNET communication data error (safety
observation function)
SD
35
Command frequency error
35.1
Command frequency error
SD
36
SSCNET receive error 2
36.1
Continuous communication data error
SD
36.2
Continuous communication data error (safety
observation function)
SD
37
Parameter error
37.1
Parameter setting range error
DB
37.2
Parameter combination error
DB
37.3
Point table setting error
DB
39
Program error
39.1
Program error
DB
39.2
Instruction argument external error
DB
39.3
Register No. error
DB
39.4
Non-correspondence instruction error
DB
No.
Name
Detail
No.
Detail name
Stop
method
*2*3
Alarm deactivation
Alarm
reset
CPU
reset
Cycling
the
power
Summary of Contents for MELSERVO-J4 series
Page 2: ......
Page 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Page 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Page 645: ......