14 USING A LINEAR SERVO MOTOR
14.4 Characteristics
491
14
Dynamic brake characteristics
• Do not use dynamic brake to stop in a normal operation as it is the function to stop in emergency.
• For a machine operating at the recommended load to motor mass ratio or less, the estimated number of
usage times of the dynamic brake is 1000 times while the machine decelerates from the rated speed to a
stop once in 10 minutes.
• Be sure to enable EM1 (Forced stop 1) after the linear servo motor stops when using EM1 (Forced stop 1)
frequently in other than emergency.
The approximate coasting distance from when the dynamic brake is activated until when the linear servo motor stops can be
calculated with the equation below.
Lmax = V
0
• (0.03 + M • (A + B • V
0
2
))
Lmax: Coasting distance of the machine [m]
V
0
: Speed when the brake is activated [m/s]
M: Full mass of the moving part [kg]
A: Coefficient (Refer to the following tables.)
B: Coefficient (Refer to the following tables.)
CAUTION
• The coasting distance is a theoretically calculated value which ignores the running load such as friction. The calculated value is considered to be longer than
the actual distance. However, if an enough braking distance is not provided, a moving part may crash into the stroke end, which is very dangerous. Install the
anti-crash mechanism such as an air brake or an electric/mechanical stopper such as a shock absorber to reduce the shock of moving parts. No linear servo
motor with an electromagnetic brake is available.
Linear servo motor (primary side)
Coefficient A
Coefficient B
LM-H3P2A-07P-BSS0
7.15
10
-3
2.94
10
-3
LM-H3P3A-12P-CSS0
2.81
10
-3
1.47
10
-3
LM-H3P3B-24P-CSS0
7.69
10
-3
2.27
10
-4
LM-H3P3C-36P-CSS0
7.22
10
-3
1.13
10
-4
LM-H3P3D-48P-CSS0
1.02
10
-3
2.54
10
-4
LM-H3P7A-24P-ASS0
7.69
10
-3
2.14
10
-4
LM-H3P7B-48P-ASS0
9.14
10
-4
2.59
10
-4
LM-H3P7C-72P-ASS0
7.19
10
-4
1.47
10
-4
LM-H3P7D-96P-ASS0
6.18
10
-4
9.59
10
-5
LM-U2PAB-05M-0SS0
5.72
10
-2
1.72
10
-4
LM-U2PAD-10M-0SS0
2.82
10
-2
8.60
10
-5
LM-U2PAF-15M-0SS0
1.87
10
-2
5.93
10
-5
LM-U2PBB-07M-1SS0
3.13
10
-2
1.04
10
-4
LM-U2PBD-15M-1SS0
1.56
10
-2
5.18
10
-5
LM-U2PBF-22M-1SS0
4.58
10
-2
1.33
10
-5
LM-U2P2B-40M-2SS0
1.47
10
-3
1.27
10
-5
LM-U2P2C-60M-2SS0
1.07
10
-3
7.66
10
-6
LM-U2P2D-80M-2SS0
9.14
10
-4
5.38
10
-6
LM-FP2B-06M-1SS0
8.96
10
-4
1.19
10
-3
LM-FP2D-12M-1SS0
5.55
10
-4
4.81
10
-4
LM-FP2F-18M-1SS0
4.41
10
-4
2.69
10
-4
LM-FP4B-12M-1SS0
5.02
10
-4
4.36
10
-4
LM-FP4D-24M-1SS0
3.55
10
-4
1.54
10
-4
LM-FP4F-36M-1SS0
1.79
10
-4
1.36
10
-4
LM-FP4H-48M-1SS0
1.15
10
-4
1.19
10
-4
LM-FP5H-60M-1SS0
1.95
10
-4
4.00
10
-5
LM-K2P1A-01M-2SS1
5.36
10
-3
6.56
10
-3
LM-K2P1C-03M-2SS1
1.17
10
-3
3.75
10
-4
Summary of Contents for MELSERVO-J4 series
Page 2: ......
Page 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Page 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Page 645: ......