17 APPLICATION OF FUNCTIONS
17.1 Scale measurement function
539
17
• MR-J4-_GF_-RJ servo amplifier
You can connect the linear encoder without using a branch cable shown in "MR-J4-_GF_ servo amplifier" for MR-J4-_GF_-RJ
servo amplifier. You can also use a four-wire type linear encoder.
■
Rotary encoder
Refer to "Servo Motor Instruction Manual (Vol. 3)" for encoder cables for rotary encoders.
• MR-J4-_GF_ servo amplifier
*1 Use a two-wire type encoder cable. A four-wire type encoder cable cannot be used.
• MR-J4-_GF_-RJ servo amplifier
You can connect the rotary encoder without using an MR-J4FCCBL03M branch cable for MR-J4-_GF_-RJ servo amplifier.
You can also use a four-wire type rotary encoder.
Servo amplifier
Linear encoder
CN2
Encoder of rotary servo motor
Encoder cable
(Refer to "Linear Encoder Instruction Manual".)
Scale
measurement
encoder
CN2L
Servo amplifier
CN2
MR-J4FCCBL03M branch cable
(Refer to section 16.2.4.)
Encoder of rotary servo motor
*1
Encoder cable
(Refer to "Servo Motor Instruction Manual (Vol. 3)".)
CN2
MOTOR
SCALE
*1
Scale
measurement
encoder
Servo motor
HG-KR
HG-MR
Servo amplifier
CN2
Encoder of rotary servo motor
Encoder cable
(Refer to "Servo Motor Instruction Manual (Vol. 3)".)
Scale
measurement
encoder
Servo motor
HG-KR
HG-MR
CN2L
Q170ENCCBL_M-A
Synchronous encoder Q171ENC-W8
(Refer to manuals of servo system controllers.)