102
3 SIGNALS AND WIRING
3.3 Explanation of power supply system
■
MR-J4-60GF4(-RJ) to MR-J4-350GF4(-RJ)
*1 A pin for preventing improper connection is inserted to N- of CNP1 connector.
■
MR-J4-10GF1(-RJ) to MR-J4-40GF1(-RJ)
Connector Receptacle assembly
Applicable wire
Stripped length
[mm]
Open tool
Manufacturer
Size
Insulator OD
CNP1
06JFAT-SAXGDK-HT10.5
AWG 16 to 14
3.9 mm or shorter
10
J-FAT-OT-XL
JST
CNP2
05JFAT-SAXGDK-HT7.5
CNP3
03JFAT-SAXGDK-HT10.5
Connector Receptacle assembly
Applicable wire
Stripped length
[mm]
Open tool
Manufacturer
Size
Insulator OD
CNP1
06JFAT-SAXGDK-H7.5
AWG 18 to 14
3.9 mm or shorter
9
J-FAT-OT (N) or J-
FAT-OT
JST
CNP2
05JFAT-SAXGDK-H5.0
CNP3
03JFAT-SAXGDK-H7.5
*1
CNP2
CNP1
CNP3
Servo amplifier
CNP2
CNP1
CNP3
Servo amplifier