8 TROUBLESHOOTING
8.2 Alarm list
285
8
65
Functional safety unit
connection error
65.1
Functional safety unit communication error 1
SD
65.2
Functional safety unit communication error 2
SD
65.3
Functional safety unit communication error 3
SD
65.4
Functional safety unit communication error 4
SD
65.5
Functional safety unit communication error 5
SD
65.6
Functional safety unit communication error 6
SD
65.7
Functional safety unit communication error 7
SD
65.8
Functional safety unit shut-off signal error 1
DB
65.9
Functional safety unit shut-off signal error 2
DB
66
Encoder initial communication
error (safety observation
function)
66.1
Encoder initial communication - Receive data error 1
(safety observation function)
DB
66.2
Encoder initial communication - Receive data error 2
(safety observation function)
DB
66.3
Encoder initial communication - Receive data error 3
(safety observation function)
DB
66.7
Encoder initial communication - Transmission data
error 1 (safety observation function)
DB
66.9
Encoder initial communication - Process error 1
(safety observation function)
DB
67
Encoder normal
communication error 1 (safety
observation function)
67.1
Encoder normal communication - Receive data error
1 (safety observation function)
DB
67.2
Encoder normal communication - Receive data error
2 (safety observation function)
DB
67.3
Encoder normal communication - Receive data error
3 (safety observation function)
DB
67.4
Encoder normal communication - Receive data error
4 (safety observation function)
DB
67.7
Encoder normal communication - Transmission data
error 1 (safety observation function)
DB
68
STO diagnosis error
68.1
Mismatched STO signal error
DB
69
Command error
69.1
Forward rotation-side software limit detection -
Command excess error
SD
69.2
Reverse rotation-side software limit detection -
Command excess error
SD
69.3
Forward rotation stroke end detection - Command
excess error
SD
69.4
Reverse rotation stroke end detection - Command
excess error
SD
69.5
Upper stroke limit detection - Command excess error
SD
69.6
Lower stroke limit detection - Command excess error
SD
70
Load-side encoder initial
communication error 1
70.1
Load-side encoder initial communication - Receive
data error 1
DB
70.2
Load-side encoder initial communication - Receive
data error 2
DB
70.3
Load-side encoder initial communication - Receive
data error 3
DB
70.4
Load-side encoder initial communication - Encoder
malfunction
DB
70.5
Load-side encoder initial communication -
Transmission data error 1
DB
70.6
Load-side encoder initial communication -
Transmission data error 2
DB
No.
Name
Detail
No.
Detail name
Stop
method
*2*3
Alarm deactivation
Alarm
reset
CPU
reset
Cycling
the
power