546
17 APPLICATION OF FUNCTIONS
17.2 Touch probe
Timing chart
*1 Turn on and off Touch Probe Signal so that both the on time and off time are 0.5 ms or longer.
Transition
No.
Object
Description
1
60B8h Bit 0, 4, 5 = 1
Enables Touch Probe1. The rising edge and falling edge are enabled.
2
60B9h Bit 0 = 1
Turns on the Touch Probe1 enable status.
3
Turns on Touch Probe Signal (TPR1).
4
60B9h Bit 1 = 1
Turns on the Touch Probe1 positive edge stored status.
4a
60BAh
Sets the latched position feedback for Touch probe position1 positive value.
5
Turns off Touch Probe Signal (TPR1).
6
60B9h Bit 2 = 1
Turns on the Touch Probe1 negative edge stored status.
6a
60BBh
Sets the latched position feedback for Touch probe position1 negative value.
7
60B8h Bit 4 = 0
Turns off Sample positive edge. Rising edge detection is disabled.
8
60B9h Bit 1 = 0
Turns off Touch Probe1 positive edge stored status.
8a
60BAh
Touch probe position1 positive value does not change.
9
60B8h Bit 4 = 1
Turns on Sample positive edge. Rising edge detection is enabled.
10
60BAh
Touch probe position1 positive value does not change.
11
Turns on Touch Probe Signal (TPR1).
12
60B9h Bit 1 = 1
Turns on the Touch Probe1 negative edge stored status.
12a
60BAh
Sets the latched position feedback for Touch probe position1 negative value.
13
60B8h Bit 0 = 0
Disables Touch Probe1.
14
60B9h Bit 0, 1, 2 = 0
Clears all the status Bit.
14a
60BAh, 60BBh
Touch probe position1 positive/negative value does not change.
Touch probe function
60B8h Bit 0
Enable Touch Probe 1
60B8h Bit 4
Trigger first event
60B8h Bit 1
Enable Sampling at positive edge
60B8h Bit 5
Enable Sampling at negative edge
Touch probe status
60B9h Bit 0
Touch Probe 1 is enabled
60B9h Bit 1
Touch Probe 1 positive edge stored
60B9h Bit 2
Touch Probe 1 negative edge stored
Touch Probe Signal
60BAh
Touch probe position 1 positive value
60BBh
Touch probe position 1 negative value
1
1
0.5 ms or longer
0.5 ms or
longer
*1
0000
0000
yyyy
xxxx
uuuu
13
7
9
14
14
14
12
8
2
4
6
3
5
4a
8a
6a
11
*1
10
12a
14a
*1
Summary of Contents for MELSERVO-J4 series
Page 2: ......
Page 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Page 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Page 645: ......