3 SIGNALS AND WIRING
3.5 Signal (device) explanations
Forward rotation stroke
end
LSP
CN3-2
To start the operation, turn on LSP and LSN. Turn it off to bring the servo motor to a slow stop
and make it servo-locked.
Setting [Pr. PD01] as follows turns the signals on automatically (always connected) in the servo
amplifier.
When LSP or LSN is turned off, [AL. 99 Stroke limit warning] occurs.
In the torque mode, this device cannot be used during normal operation. It can be used during
the magnetic pole detection in the linear servo motor control mode and the DD motor control
mode. Also, when the magnetic pole detection in the torque mode is completed, this signal will
be disabled.
DI-1
Reverse rotation stroke
end
LSN
CN3-12
Proximity dog
DOG
CN3-19
Turning off DOG will detect a proximity dog. The polarity for dog detection can be changed with
[Pr. PT29].
DI-1
Proportional control
PC
Turn PC on to switch the speed amplifier from the proportional integral type to the proportional
type.
If the servo motor at a stop is rotated even one pulse due to any external factor, it generates
torque to compensate for a position shift. When the servo motor shaft is to be locked
mechanically after positioning completion (stop), switching on the PC (Proportion control) upon
positioning completion will suppress the unnecessary torque generated to compensate for a
position shift.
When the shaft is to be locked for a long time, switch on the PC (Proportion control) at the same
time to make the torque less than the rated one.
Do not use PC (Proportional control) in the torque mode. When PC (Proportional control) is
used in the torque mode, operation may be performed at a speed exceeding the speed limit
value.
DI-1
Gain switching
CDP
Turn on CDP to use the values of [Pr. PB29] to [Pr. PB36] and [Pr. PB56] to [Pr. PB60] as the
load to motor inertia ratio and gain values.
DI-1
Fully closed loop
selection
CLD
This is used when the semi closed loop control/fully closed loop control switching is enabled
with [Pr. PE01].
Turn off CLD to select the semi closed loop control, and turn on CLD to select the fully closed
loop control.
This is used with servo amplifiers with software version A1 or later.
DI-1
Device
Symbol
Connect
or pin
No.
Function and application
I/O
division
*1 0: Off
1:
On
Input device
*1
Operation
LSP
LSN
CCW direction
Positive direction
CW direction
Negative
direction
1
1
1
0
1
0
0
0
[Pr. PD01]
Status
LSP
LSN
Automatic on
_ 4 _ _
_ 8 _ _
_ C _ _
Automatic on
Automatic on
Automatic on
[Pr. PT29]
Polarity for proximity dog detection
Detection with on
_ _ _ 0
_ _ _ 1
Detection with off