42
1 FUNCTIONS AND CONFIGURATION
1.7 Structure
1.7
Structure
Parts identification
200 V class
■
MR-J4-200GF(-RJ) or less
The diagram shows MR-J4-10GF-RJ.
CAUTION
• When the servo amplifier is used for CC-Link IE Field Network, use the CN1A connector and CN1B connector. Do not connect these connectors to other than
CC-Link IE Field Network. Otherwise, a malfunction may occur.
• When the servo amplifier is used for CC-Link IE Field Network Basic, use the CN1A connector only. Do not connect this connector to other than CC-Link IE
Field Network Basic. Otherwise, a malfunction may occur.
No.
Name/Application
Detailed explanation
(1)
Display
The 3-digit, 7-segment LED shows the servo status and the alarm number.
Page 134 Switch setting and display of
(2)
Station number setting rotary switch (SW2/SW3)
Used to set the station number of the servo amplifier.
(3)
Mode select switch (SW1)
To change mode to the test operation mode, set the switch. (SW1-1)
(4)
USB communication connector (CN5)
Used to connect a personal computer.
(5)
I/O signal connector (CN3)
Used to connect digital I/O signals.
(6)
STO input signal connector (CN8)
Used to connect the MR-J3-D05 safety logic unit and external safety relay.
Page 586 MR-J3-D05 Safety logic unit
(7)
Ethernet cable connector (CN1A)
Used to connect the controller or the servo amplifier.
Page 59 Configuration including
Page 137 CC-Link IE Field status
(8)
Ethernet cable connector (CN1B)
Used to connect the controller or the servo amplifier.
(9)
Encoder connector (CN2)
Used to connect the servo motor encoder or external encoder. Refer to the following for the
compatible external encoders.
assignment
"Servo Motor Instruction Manual (Vol. 3)"
(10)
Battery connector (CN4)
Used to connect the battery for absolute position data backup.
1
ON
2
(6)
(18)
(13)
(10)
(17)
(9)
(5)
(7)
(11)
Bottom
(16)
(15)
(8)
(4)
(14)
Side
(12)
(19)
(20)
(1)
(3)
(2)
Inside of the display cover