4 STARTUP
4.3 Switch setting and display of the servo amplifier
4.3
Switch setting and display of the servo amplifier
Switching to the test operation mode and setting station No. are enabled with switches on the servo amplifier.
On the servo amplifier display (three-digit, seven-segment LED), check the status of communication with the controller at
power-on, and the station number, and diagnose a malfunction at occurrence of an alarm. The communication status of the
CN1A connector and CN1B connector can be checked with the LED.
Switches
• Turning "ON (up)" all the mode select switches (SW1) enables an operation mode for manufacturer setting
and displays "off". The mode is not available. Set the mode select switches (SW1) correctly according to
this section.
• Cycling the main circuit power supply and control circuit power supply enables the setting of each switch.
The following explains the mode select switches and the station number setting rotary switch.
Test operation select switch (SW1-1)
To use the test operation mode, turn "ON (up)" the switch. Turning "ON (up)" the switch enables the test operation mode. In
the test operation mode, the functions such as JOG operation, positioning operation, and machine analyzer are available with
MR Configurator2.
Station number setting rotary switch (SW2/SW3)
Set the station number of the servo amplifier in hexadecimal. When the station number is set to a value other than "01h (1)" to
"78h (120)", [AL. 11.1 Station number setting error] will occur.
WARNING
• When switching the station number setting rotary switch (SW2/SW3) and mode select switch (SW1), use insulated screw driver. Do not use a metal screw
driver. Touching patterns on electronic boards, lead of electronic parts, etc. may cause an electric shock.
3-digit, 7-segment LED
Station number setting rotary switch (upper) (SW2)
Station number setting rotary switch (lower) (SW3)
Mode select switch (SW1)
1
ON
2
For manufacturer setting (SW1-2)
Test operation select switch (SW1-1)
1
ON
2