448
12 ABSOLUTE POSITION DETECTION SYSTEM
12.1 Summary
Structure
The following shows the structure of the absolute position detection system. Refer to the following for each battery
connection.
Parameter setting
Absolute position detection system selection
Set "_ _ _ 1" in [Pr. PA03] to enable the absolute position detection system.
[AL. E3 Absolute position counter warning] selection
When a simple motion module QD77GF_ or RD77GF_ is used, set [Pr. PC18] to "_ _ 0 _".
Controller
Servo amplifier
Servo motor
CN2
CN1A
Battery
CN4
Absolute position detection system selection
0: Disabled (used in incremental system)
1: Enabled (used in absolute position detection system)
[Pr. PA03]
1
[AL. E3 Absolute position counter warning] selection
0: Disabled
1: Enabled
[Pr. PC18]