11 OPTIONS AND PERIPHERAL EQUIPMENT
11.2 Regenerative options
349
11
MR-RB032
• TE1 terminal
Applicable wire size: 0.2 mm
2
to 2.5 mm
2
(AWG 24 to 12)
Tightening torque: 0.5 to 0.6 [N•m]
• Mounting screw
Screw size: M5
Tightening torque: 3.24 [N•m]
TE1
30
15
99
1.6
119
144
12
156
168
6
6
5
˳
6 mounting hole
Approx. 6
Approx. 12
Approx. 20
[Unit: mm]
Mass: 0.5 [kg]
G3
G4
P
C
Summary of Contents for MELSERVO-J4 series
Page 2: ......
Page 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Page 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...