404
11 OPTIONS AND PERIPHERAL EQUIPMENT
11.10 Molded-case circuit breakers, fuses, magnetic contactors
11.10
Molded-case circuit breakers, fuses, magnetic
contactors
For the selection when the MR-J4-_GF-RJ servo amplifier is used with the DC power supply input, refer to the
following.
Page 567 Molded-case circuit breakers, fuses, magnetic contactors
For main circuit power supply
When using a fuse instead of the molded-case circuit breaker, use the one having the specifications given in this section.
CAUTION
• To prevent the servo amplifier from smoke and a fire, select a molded-case circuit breaker which shuts off with high speed.
• Always use one molded-case circuit breaker and one magnetic contactor with one servo amplifier.
Servo amplifier
Molded-case circuit breaker
Fuse
Frame, rated current
Voltage AC [V]
Class
Current [A] Voltage AC
[V]
Power factor
improving
reactor is not
used
Power factor
improving
reactor is used
MR-J4-10GF(-RJ)
30 A frame 5 A
30 A frame 5 A
240
T
10
300
S-N10
S-T10
MR-J4-20GF(-RJ)
30 A frame 5 A
30 A frame 5 A
MR-J4-40GF(-RJ)
30 A frame 10 A
30 A frame 5 A
15
MR-J4-60GF(-RJ)
30 A frame 15 A
30 A frame 10 A
20
MR-J4-70GF(-RJ)
30 A frame 15 A
30 A frame 10 A
MR-J4-100GF(-RJ)
(3-phase power
supply input)
30 A frame 15 A
30 A frame 10 A
MR-J4-100GF(-RJ)
(1-phase power
supply input)
30 A frame 15 A
30 A frame 15 A
30
MR-J4-200GF(-RJ)
30 A frame 20 A
30 A frame 20 A
40
S-N20
S-T21
MR-J4-350GF(-RJ)
30 A frame 30 A
30 A frame 30 A
70
S-N20
S-T21
MR-J4-500GF(-RJ)
50 A frame 50 A
50 A frame 50 A
125
S-N35
S-T35
MR-J4-700GF(-RJ)
100 A frame 75 A
60 A frame 60 A
150
S-N50
S-T50
MR-J4-11KGF(-RJ)
100 A frame 100 A
100 A frame 100 A
200
MR-J4-15KGF(-RJ)
125 A frame 125 A
125 A frame 125 A
250
S-N65
S-T65
MR-J4-22KGF(-RJ)
225 A frame 175 A
225 A frame 175 A
350
S-N95
S-T100