11 OPTIONS AND PERIPHERAL EQUIPMENT
11.11 Power factor improving DC reactors
407
11
11.11
Power factor improving DC reactors
The following shows the advantages of using power factor improving DC reactor.
• It improves the power factor by increasing the form factor of the servo amplifier's input current.
• It decreases the power supply capacity.
• The input power factor is improved to about 85%.
• As compared to the power factor improving AC reactor (FR-HAL-(H)), it decreases the loss.
When connecting the power factor improving DC reactor to the servo amplifier, always disconnect P3 and P4. If it remains
connected, the effect of the power factor improving DC reactor is not produced.
When used, the power factor improving DC reactor generates heat. To dissipate heat, therefore, maintain a minimum
clearance of 10 cm each at the top and bottom, and 5 cm at the sides.
200 V class
*1 Use this for grounding.
*2 When using the power factor improving DC reactor, remove the short bar between P3 and P4.
*3 Maximum dimensions. The dimension varies depending on the input/output lines.
*4 Selection conditions of wire size are as follows.
Wire type: 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: Single wire set in midair
Servo amplifier
Power factor
improving
DC reactor
Dimensions [mm]
Terminal
size
Mass
[kg]
Wire [mm
2
W
W1
H
D
D1
D2
D3
d
MR-J4-10GF(-RJ)
MR-J4-20GF(-RJ)
FR-HEL-0.4K
70
60
71
61
21
M4
M4
0.4
2 (AWG 14)
MR-J4-40GF(-RJ)
FR-HEL-0.75K
85
74
81
61
21
M4
M4
0.5
MR-J4-60GF(-RJ)
MR-J4-70GF(-RJ)
FR-HEL-1.5K
85
74
81
70
30
M4
M4
0.8
MR-J4-100GF(-RJ)
FR-HEL-2.2K
85
74
81
70
30
M4
M4
0.9
2-d mounting hole
(Varnish is removed from right mounting
hole (face and back side).)
*1
D or less
W ± 2
W1
H
P P1
*2
Servo amplifier
P3
P4
FR-HEL
5 m or less
Summary of Contents for MELSERVO-J4 series
Page 2: ......
Page 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Page 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Page 645: ......