Jabiru J450 Constructors Manual
Pre-Paint>Fuselage>Empennage>Fit vertical tail fin
Tuesday, April 6, 2010
92 of 343
Next day, shorten the VHF coax cable to length, and fit ferrite toroids, crimp 4.5mm
electrical ring terminal connectors to the inner cable and the outer coax sheath and fit heat
shrink tubing over the terminal joins, as shown in the sketch below.
Screw the inner cable to the TOP section and the braided coax sheath to the LOWER section.
Tuck any excess cable back into the vertical fin and seal completely with silicone sealant.
Fit the static probe assembly
Assemble the static probe: using a drop of Loctite fit the bullet-nose end to the static tube,
making sure that the vent hole (circled) will be horizontal when the static probe is installed.