HTX30 Product Manual
Fault Finding
6-11
EIM alarms
Name
SCP text
Description
Priority
Engine local
mode
LOCAL
The operator has taken control at the engine local control panel
Warning
SCP demand
lost
DEMND / LOST This module has lost in control demand from the SCPs
Alarm
Gearbox
feedback
invalid
GBXFB
The gearbox feedback lines are in an invalid combination
Alarm
RPM feedback
invalid
RPMFB
The engine is on and the RPM feedback is outside the engine RPM
range
Warning
Voltage
reference
invalid
VRFIN
Ratiometric voltage reference is enabled but out of range
Alarm
Actuator drive
fault
ACDRV
The motor drive to the actuator has dropped out
Alarm
RPM followup RPMFO
The engine demand is stable but the engine has not followed up,
or it no longer matches demand
Warning
Throttle
actuator
shutdown
THRTL/ SHTDN The throttle has been returned to idle and the actuator has
disengaged due to not being able to meet the operators demand.
Subcodes:
0 - None
1 - OOR
2 - Pinched
3 - Stuck
Warning
Throttle
actuator stuck
Thrtl / stuck
The throttle actuator could not move to the requested setting and
has stopped at a lower throttle
Alarm
CID alarms
Name
SCP text
Description
Priority
Handle
connection
fault
HNDLE/FAULT
The JETanchor Mouseboat cannot communicate with the handle
board
Alarm
Input out of
range
INOOR
A input signal from a pot has gone out of range
Alarm
XCI alarms
Name
SCP text
Description
Priority
Control conflict CTRL / CNFLT
More than one station is in control
Warning
Cannot claim
address
ADDR / NOCLM At least one J1939 node could not claim an address
Alarm