Appendix
HTX30 Product Manual
8-46
Calibration group
Short name: Calib
Name
SCP text
Description
Min
Max
Default Units
Access
4mA demand D 4mA
The DAC value to write for 4.0 mA.
0
4095
737
F
20mA demand D20mA
The DAC value to write for 20.0 mA.
0
4095
3685
F
0V demand
D 0V
The DAC value to write for 0.0 V.
0
4095
0
F
12V demand
D 12V
The DAC value to write for 12.0 V.
0
4095
3831
F
0V feedback
F 0V
The ADC value that corresponds to 0.0 V on the voltage
feedback input.
0
1023
0
F
12V feedback F 12V
The ADC value that corresponds to 12.0 V on the voltage
feedback input.
0
1023
473
F
Throttle calibration group
Short name: Thrtl / Cal
Name
SCP text
Description
Min
Max
Default Units
Access
Use Throttle calibration Use?
Set to apply throttle calibration.
0
1
0
D
Throttle calibration 40% Thr40
The % FSD demand value to apply for 40% throttle.
5
90
40
D
Throttle calibration 70% Thr70
The % FSD demand value to apply for 70% throttle.
10
95
70
D
Throttle calibration 90% Thr90
The % FSD demand value to apply for 90% throttle.
15
99
90
D
Save and reload group
Short name: Save / Relod
Name
SCP text
Description
Min
Max
Default Units Access
Load factory values
LoadF
D
Save to ship
Save
D
Save to character
SaveC
F
Save Rom Defs to
Character Factory
SaveR
Sets the factory defaults of the character rom to the hard
coded Rom defaults, i.e total reset
F
Clear Defaults Alarm Clear / Defs Clears the Default Alarm orginating from the Character Rom
D
Summary of Contents for HTX30
Page 1: ...HTX30 HTX30 Product Manual R0A5 blue ARROW...
Page 8: ...1 vi...
Page 20: ......
Page 26: ......
Page 178: ......
Page 181: ...Notes...