Fault Finding
HTX30 Product Manual
6-8
Name
SCP text
Description
Priority
Backup
communication
BAKUP /
COMMS
Comms error with the backup processor
Subcodes:
0 - Link
1 - Param
2 - Tx Notify
Warning
Fallback out of
range
FALBK / RANGE Backup processor has detected that fallback pwm is out of range
Warning
Backup drive
timeout
BAKUP / TMOUT Backup processor has a drive timeout
Warning
Backup
feedback error
BAKUP / FDBCK Backup processor has detected str or reverse feedback out of
range
Alarm
Normal mode
unavailable
NORML /
UNAVL
The JIM has been instructed to place the system into normal by
the scp, but was unable to do so after a timeout
Alarm
Engine status
lost
ENGST / LOST
The JIM has lost the periodic feedback message from the
corresponding EIM
Alarm
Jet move with
no power
JET / MOVED
The JIM has no hydraulic power, but the jet is still moving in the
direction, it is been driven
Warning
Voltage out of
range
VOLT / OOR
JIM voltage detection
Subcodes:
0 - Primary
1 - Secondary
Alarm
Feedback Span
out of range
FBKSPN / OOR
The fbk span is out of range, normally too small travel on fbk
sensor, between limits
Subcodes:
0 - Steering
1 - Reverse
2 - StrMargin
3 - RevMargin
Warning
Backup voltage
out of range
BAKUP / VOLT
Backup processor has measured an out of range drive voltage
Warning
Internal
Voltage out of
range
INTVLT / OOR
JIM internal voltage detection
Subcodes:
0 - Primary
1 - Secondary
Alarm