Fault Finding
HTX30 Product Manual
6-10
Name
SCP text
Description
Priority
Real time clock
fault
CLKFT
The real time clock battery is missing, has never been set, or the
internal battery has failed.
Subcodes:
0 - Time data invalid
1 - Data lost
2 - Time invalid
The battery is not user replaceable but the system will continue to
work.
The internal fault log may be affected
Warning
Autopilot out
of range
APRNG
The autopilot demand signal has gone out of range
Alarm
Assigning
locations failed
LOCAT / FAILD
The assigning of addresses (association) phase last run on this SCP
failed. Fix by checking the network and re-enumerating.
Subcodes:
0 - OK: No error. Association completed successfully
1 - Running: Association is currently running. The actual error
code will be updated late
2 - No JIMs: No JIMs were found
3 - JIM count: Either three or more JIMs were found or a
different number of JIMs to what is locally configured were
found
4 - JIM location: Could not automatically discover the location
of at least one JIM
5 - Unused - was JIM Port Location
6 - Unused - was JIM Starboard Location
7 - SCP Count: More than three SCPs were found
8 - No SCPs: No SCPs were found
9 - Primary SCPs: More than one SCP seems to be at the first
station
10 - Default SCP Location: Could not discover the location of
one or more SCPs. The SCP has been given an unused location
11 - CID location: Could not discover the location of one or
more CIDs. The CID location is based off the directly
connected SCP location
12 - No CIDs at Station
13 - EIM count: Found more than two EIMs or found a
different number of EIMs to JIMs
14 - EIM no JIMs: Found no JIMs so the EIM location couldn't
be se
15 - Unused - was EIM Same JIMs
16 - EIM too many JIMs: More than one EIM is connected to
the same JI
17 - EIM no JIM location: The EIM is connected to a JIM and
the JIM is at an unknown location
18 - EIM JIM location: The EIM appears to be at the same
location as another EI
19 - Unused - was EIM Port Location
20 - Unused - was EIM Starboard Location
21 - JACM count: Found two or more JACMs
Alarm
Incorrect
number of JIMs
INCOR / JIMS
The number of JIMs detected is different to the number expected.
This can happen in a twin jet installation when one JIM is faulty at
enumeration time or if the SCP in single jet installation is set to
expect two jets
Alarm
Summary of Contents for HTX30
Page 1: ...HTX30 HTX30 Product Manual R0A5 blue ARROW...
Page 8: ...1 vi...
Page 20: ......
Page 26: ......
Page 178: ......
Page 181: ...Notes...