Appendix
HTX30 Product Manual
8-54
Advanced group
Short name: Advcd
Name
SCP text Description
Min
Max
Default
Units Access
Lockable
Lock?
Set to enable station locking. Station locking
allows the operator to lock the control at this
station, preventing any other from taking
control.
0
1
0
C
Key beeps
KBeep
Clear to turn off the key beeps from the SCP
internal sounder.
0
1
TRUE
C
Backlight can turn
off
BkOff
Set to turn the backlight and lamps off when
dimmed to the lowest setting.
0
1
0
C
Hide in control
indicator
NoICI
Don't show the in control indicator when this
station is in control.
0
1
0
D
Allow engine sync
Sync?
Clear to disable the engine throttle sync mode.
FALSE
TRUE
TRUE
C
Engine sync margin EsMrg
Percentage that the throttle demand can be out
before dropping out of throttle sync mode.
0
100
30
%
C
Maximum idle
engine demand
IdMax
The highest engine demand that can be set using
the idle adjust buttons.
0
80
20
%
C
Number of idle
adjust steps
IdStp
The number of steps available on the idle adjust
buttons.
2
50
4
D
Simulate mode
Simul
Internal testing parameter. Set to enable jet
simulation mode.
JMR_MODE
_NORMAL
JMR_MODE_
SIMULATE |
JMR_MODE_
CYCLE
JMR_MODE
_NORMAL
F
Reverse steering
assist level
RvStr
The level of reverse duct assisted steering
available when the helm is hard over. Sets how
far down the reverse duct on the inside of the
turn will come down. For example, setting this to
100% will cause the port reverse duct to come
fully down when turning hard to port. Set to zero
to disable this feature.
0
100
100
%
C
Association error
code
AsErr
The error that occurred during the last attempt
at association. Zero if there was no error.
0
65535
0
F
Show status
Stat?
If set, waterjet status information is displayed
when the SCP is idle.
0
1
0
F
Has no CIDs
NoCID
Set if this SCP is intended to have no CIDs. Used
when this SCP is for an autopilot interface only.
0
1
0
D
Calibration group
Short name: Calib
Name
SCP text
Description
Min
Max
Default Units
Access
Autopilot -10 V
demand
AD-10
The ADC value that corresponds to -10 V demand
0
1000
685
F
Aut10 V
demand
AD+10
The ADC value that corresponds to +10 V demand
3000
4095
3523
F
Autopilot -10 V
feedback
AF-10
The DAC value that corresponds to -10 V feedback
0
200
31
F
Aut10 V
feedback
AF+10
The DAC value that corresponds to +10 V feedback
800
1023
1001
F
Save and reload group
Short name: Save / Relod
Name
SCP text
Description
Min
Max
Default Units
Access
Load factory values LoadF
D
Save to ship
Save
D
Summary of Contents for HTX30
Page 1: ...HTX30 HTX30 Product Manual R0A5 blue ARROW...
Page 8: ...1 vi...
Page 20: ......
Page 26: ......
Page 178: ......
Page 181: ...Notes...