Appendix
HTX30 Product Manual
8-50
Sensors group
Short name: Sens
Name
SCP text
Description
Min
Max
Default Units
Access
JHPU oil temp
OilT
Maximum JHPU oil temperature, before an alarm
condition. Set to zero to disable the oil temperature
sensor
0
200
70
degC
D
JHPU oil level
OilL
Enables the JPHU oil level sender
0
1
1
D
Bearing oil temp
switch
brgT
Enables the bearing oil temperature switch detection
0
1
0
D
Jet RPM pulses per
rev
Jet / Rpm /
PPR
The number of pulses per rev the jet RPM senor will be
triggered per revolution, Set to zero to disable the jet
Rpm sensor
0
12
3
D
Jet RPM staggered
Jet / Rpm /
Stagd
Enables staggered pulses on the jet RPM sensor, which
allows direction detection. This only works when the jet
RPM sensor is enabled
0
1
1
D
Backup group
Short name: Bkp
Name
SCP text
Description
Min
Max
Default Units
Access
Str Kp
StrKp
Overrides the automatic backup str kp control value. Set
to zero to use automatic value
0
100
0
C
Rev Kp
RevKp
Overrides the automatic backup rev kp control value.
Set to zero to use automatic value
0
100
0
C
Str Ki
StrKi
Overrides the automatic backup str ki control value. Set
to zero to use automatic value
0
100
0
C
Rev Ki
RevKi
Overrides the automatic backup rev ki control value. Set
to zero to use automatic value
0
100
0
C
Eng Dmd Mode
Eng / Mode The backup engine dmd interface mode:
Vo - Voltage
Cu - Current
ID - Increment/Decrement
Pl - PWM voltage
Pd - PWM open drain
Pp - PWM open drain w/pullup
C
Eng Dmd High
Eng / High
The backup eng dmd high value
0
16383
16000
C
Eng Dmd Low
Eng / Low
The backup eng dmd low value
0
16383
100
C
Eng Dmd A
EngA
The backup eng dmd A value
0
16383
0
C
Eng Dmd B
EngB
The backup eng dmd B value
0
16383
0
C
Eng Dmd Invert
Eng / Inv
Inverts the engine dmd output
0
1
0
C