HTX30 Product Manual
Commissioning
5-13
Click
OK
to continue.
Upper limit of the reverse duct.
Lift the duct into the fully raised position.
Click
OK
to continue.
Lower limit of the reverse duct.
Lower the duct into the fully lowered position.
Click
OK
to continue.
Zero speed position for the reverse duct.
Move the duct into the zero speed position. This position will need to be approximated, and fine-tuned
once the vessel is in the water.
Click
OK
to continue.
Repeat the calibration procedure on all other jet interface modules.
This completes the unpowered calibration of the jet interface module.
The vessel can be manoeuvred once launched, but some settings need to be fine-tuned. This is done by
running the powered Jet Setup (
►
page 5-23).
If the control system includes an external control interface (XCI) module or JETanchor control module
(JACM), continue with the following sections to set up those modules.
Stage 2 Post launch (powered calibration)
Can only be done when the jets are in the water, have hydraulic power and are free to move.
Automatically detects and sets many of the jet settings.
A powered calibration must be done to set up the correct values for the jets and reverse ducts. See the
jet setup section for a guide to powered calibration (
►
Summary of Contents for HTX30
Page 1: ...HTX30 HTX30 Product Manual R0A5 blue ARROW...
Page 8: ...1 vi...
Page 20: ......
Page 26: ......
Page 178: ......
Page 181: ...Notes...