Appendix
HTX30 Product Manual
8-56
Docking group
Short name: Dockn
Name
SCP text
Description
Min
Max
Default Units
Access
Aside throttle
AsiTh
The percentage throttle demand when a docking input
is pressed hard to port or hard to starboard.
0
80
30
%
C
Ahead throttle
AhdTh
The percentage throttle demand when a docking input
is pushed hard ahead.
0
80
15
%
C
Astern throttle
AstTh
The percentage throttle demand when a docking input
is pushed hard astern.
0
80
15
%
C
Z axis throttle
Z Th
The percentage throttle demand when a docking input
with a third axis is rotated hard to port or hard to
starboard.
0
80
30
%
C
Helm compensation Compn
The number of degrees of steering offset needed to
stop the vessel rotating when under docking control.
See the manual for further instructions.
0
200
50
degrees/10 C
50% thrust demand 50Thr
Internal parameter. The reverse position for the ahead
reverse duct when moving sideways. Trim to stop the
vessel from moving ahead or astern.
10
80
35
%
D
100% demand
DmFwd
Internal parameter. The reverse position for the reverse
ducts when moving fully ahead. Set to position the duct
just above the jet stream.
50
100
95
%
D
Save and reload group
Short name: Save / Relod
Name
SCP text
Description
Min
Max
Default Units
Access
Save to ship
Save
D
Load factory values
LoadF
D